3 min readUpdated 23 September, 2026

The base controls the alignment of every wall, ceiling joint and door.

In short: the floor should be level within the project tolerance, commonly checked against ±3 mm per metre, and must be dry, clean and load-bearing.

Check the whole footprint with a laser or long straightedge. Remove high spots and correct low areas with a suitable permanent method. Do not rely on scattered packing pieces unless the floor system explicitly allows them; Algor load ratings can be reduced when spacers are used.

For a no-floor chiller, verify hygiene, sealing and thermal suitability of the slab. For a freezer, confirm insulation, vapour control and protection against ground frost.

Floor requirements

Floor faults are the single most common — and most expensive — root cause of a failed install.

RequirementSpecificationWhy it matters
LevelnessLevel within ±3 mm per metre (laser level or long spirit level)A sloping base throws walls out of plumb, opens joints, and breaks seals — cold air escapes
SurfaceClean, dry, smooth, swept; no oil, grease, or standing waterFloor panels must sit flat without rocking; debris in joints prevents full cam engagement
Load capacityMust carry room + contents + equipment + personnel. MTH requires the supporting surface to be level and load-rated by a qualified specialist for the mass and maximum load of the room, with structural calculations to local building regulationsCollapse or deflection of the building structure is outside the manufacturer's liability — the calculation is the customer's responsibility
DrainageNo water may collect beneath floor panelsStanding water below the insulation causes corrosion, frost heave, and odour

The floor panel carries its own published rating, which is a different figure from what the slab beneath it can take. MTH supplies three types: pedestrian 1,500 kg/m² for foot traffic and shelving, reinforced 3,000 kg/m² for hand pallet trucks and pallets, and drive-in 4,000 kg/m² for forklifts — with a loading ramp available where forklifts or pallet trucks enter the room. Match the type to the traffic the room will actually see; the full static, dynamic and point-load figures are in the manufacturer documentation: Download the documents.

If the floor is out of tolerance, correct it before delivery — typically with a self-levelling compound for broad slope, or shims under individual floor panels for local dips.

Floor levelness check — a laser level projects a reference line across the slab, with a ±3 mm per metre tolerance; on an uneven slab a panel rests on a high spot and rocks, on a level slab it sits flat and seated.
Floor levelness check before install

Do you need floor panels?

Insulated floor panels go down first and are essential for all freezers and for any room built over an unconditioned or heated space. They may be omitted only for chillers sitting on a suitable, already-insulated, level, sealed slab.

In the Frostbox range the "without floor" option is offered for the Cold Room 80 mm configuration only; freezing rooms always include an insulated floor. Omitting the floor lowers cost and removes the threshold step, but it shifts responsibility for insulation, levelness, and moisture sealing onto the building slab — confirm that specification first.

See Panel specifications for thickness and floor-panel detail.


Unsure whether your slab is level or load-rated enough? Send your drawings and we'll review them before delivery — contact [email protected].