The main architectures are direct expansion (DX) and indirect secondary-loop systems. Refrigerant choice is a separate decision.

In short: compare load, number of rooms, piping, safety, service and regulation.

CO₂, ammonia and propane can appear in different arrangements; “natural refrigerant” is not a third piping architecture.

The refrigeration cycle in 60 seconds

Every cold-room system runs the same vapour-compression cycle. Four components move heat "uphill" from the cold interior to the warmer outdoors:

  • Compressor — raises refrigerant pressure (and temperature), driving the cycle.
  • Condenser — rejects heat outdoors; refrigerant condenses to liquid.
  • Expansion device — drops pressure, sharply cooling the liquid.
  • Evaporator — absorbs heat from the room; refrigerant boils back to vapour. A fan circulates the chilled air.

What changes between architectures is where the phase change happens and which fluid touches the inside of the cold room. That single distinction drives every trade-off — leak risk, charge size, efficiency, and cost.

Closed refrigeration loop with the evaporator inside the cold room — heat from the room air flows into the evaporator, where the cooling happens; the refrigerant carries it to the compressor and on to the condenser, which releases the heat outside, then back through the expansion valve to the evaporator.
The refrigeration cycle

What characterises a refrigerant

Four properties decide what regulators and safety codes will allow:

PropertyWhat it means
GWPWarming effect of 1 kg of the gas vs 1 kg of CO₂ over 100 years (CO₂ = 1 by definition).
FlammabilitySafety class A1 (none) → A3 (highly flammable); A2L = mildly flammable.
ToxicityB-class refrigerants (e.g. ammonia) are toxic.
Operating pressureDrives pipe, valve, and compressor design (CO₂ runs very high).

These four properties — not just GWP — govern the architecture and refrigerant you can specify, and they are tightening fast under EU F-gas rules.

The three architectures at a glance

ArchitectureRefrigerant in the room?Best fit
Direct expansion (DX)Yes — evaporates in the room coilSingle small–medium room
Secondary loopNo — benign glycol/brine in the roomMulti-room, multi-zone, large
Natural refrigerantDepends — used as DX, primary, or self-containedFuture-proof builds of any size

Questions about which system suits your project? Contact [email protected].