Refrigeration does not destroy heat. It carries heat from the cold room to a warmer place where the condenser can release it.

In short: evaporator absorbs, compressor drives, condenser releases, expansion device reduces pressure.

The vapour-compression cycle

Every cold room — whatever its refrigerant or layout — runs the same vapour-compression cycle. A refrigerant circulates through four components, changing between liquid and gas to carry heat from inside to outside.

ComponentLocationWhat it doesRefrigerant state in → out
CompressorOutside (condensing unit)Raises refrigerant pressure and temperature, driving the cycleLow-pressure gas → hot high-pressure gas
CondenserOutsideRejects heat to ambient air; fans accelerate the transferHot gas → warm liquid
Expansion deviceAt the evaporator inletDrops pressure sharply, which sharply drops temperatureWarm liquid → cold low-pressure liquid/vapour
EvaporatorInside the cold roomAbsorbs heat from room air across finned coils; a fan circulates airCold liquid → cool gas

The cool gas returns to the compressor and the loop repeats.

The one fact worth remembering

The evaporator is the only part inside the room, and it is where heat is captured. Everything else — compressor, condenser, expansion valve — exists to carry that heat outside and throw it away. When you understand this, the whole machine makes sense: cold air at the evaporator coil is simply room air that has had its heat absorbed and shipped outdoors.

Closed refrigeration loop with the evaporator inside the cold room — heat from the room air flows into the evaporator, where the cooling happens; the refrigerant carries it to the compressor and on to the condenser, which releases the heat outside, then back through the expansion valve to the evaporator.
The refrigeration cycle

Selecting the architecture that runs the cycle

The cycle is universal, but how it is implemented — direct expansion, secondary loop, or natural refrigerants — and which refrigerant family runs it are engineering choices. For Frostbox installations these use the real Daikin unit families (GS, SP-O, DB-O, SAR, SAS, PC, GM-R290). For how to select the architecture and refrigerant, see Refrigeration system selection. For the unit families themselves, see Refrigeration units.


Recommendations reflect the MTH Algor panel system and Daikin refrigeration supplied by Frostbox. For help matching a unit to your application, contact [email protected].

Was this article helpful?
menucross-circle
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram