Made in Italy by Daikin (Zanotti) | R290 natural refrigerant | Through-ceiling plug-in
| Application | Cold room (-5…10°C) |
| Recommended room volume | up to 27.95 m³; tropical +43°C: up to 14 m³ |
| Cooling capacity | 3.1 kW |
| Refrigerant | R-290 (GWP 3) |
| Power input | 1.76 kW / 8.22 A |
| Power supply | 230 / 1N~ / 50 V/Ph/Hz |
| Defrost | Hot gas |
| Sound level | 51 dB(A) |
| Unit dimensions (H×W×D) | 427 × 1044 × 1074 mm |
PC is the straightforward ceiling monobloc: condenser and evaporator in one housing, mounted through the cold room ceiling, plugged into a 230 V socket. M-models cover chiller duty (−5…+10 °C), B-models freezer duty (−25…−15 °C).
It fits ceiling panels from 100 to 200 mm and ships factory-charged with R290 — no refrigerant work, no plant room, no roof unit.
Complete plug-in unit. Compressor, condenser, evaporator, controller and hot-gas defrost in a single ceiling housing.
Panel compatibility 100–200 mm. Designed for standard cold room ceiling panels; mounting template included in the manual.
Single-phase 230 V. Every PC model runs on ordinary single-phase supply.
Hot-gas defrost. Faster and more efficient than electric defrost heaters.
R290 (propane) is a natural refrigerant with a Global Warming Potential of 3. The synthetic refrigerants still common in older cold room systems — R404A, R449A — sit between 1,000 and 4,000. The difference is not cosmetic: the EU F-Gas Regulation tightens quotas on high-GWP refrigerants year after year, making older systems progressively more expensive to service.
A unit running on R290 sidesteps that problem entirely. The refrigerant charge is small (below 150 g per circuit on this range), the circuit is hermetically sealed at the factory, and there is no F-Gas phase-down clock ticking over your investment.
Cut the ceiling opening to template, lift the unit into place, seal, plug in. The circuit is hermetically sealed at the factory — installation without F-gas certification.
Manufacturer-recommended room volumes (35°C ambient, PIR insulation panels):
| Model | Room temperature | Recommended volume |
|---|---|---|
| BPC1112 | -25…-15°C | up to 2.72 m³ |
| MPC1107 | -5…10°C | up to 5.63 m³ |
| BPC2224 | -25…-15°C | up to 7.89 m³ |
| MPC1110 | -5…10°C | up to 9.26 m³ |
| BPC4336 | -25…-15°C | up to 11.74 m³ |
| MPC2112 | -5…10°C | up to 15.33 m³ |
| BPC4345 | -25…-15°C | up to 26.55 m³ |
| MPC3220 ← this model | -5…10°C | up to 27.95 m³ |
| MPC3224 | -5…10°C | up to 37.58 m³ |
| MPC4336 | -5…10°C | up to 62.75 m³ |



Please review your choices for the door positioning and opening side before submitting