Made in Italy by Daikin (Zanotti) | Pre-charged quick couplings | Self-install, no F-gas
Complete split set — one purchase item, factory matched.
| Application | Cold room (-5…10°C) |
| Recommended room volume | up to 15 m³; tropical +43°C: up to 7.5 m³ |
| Cooling capacity | 1.8 kW |
| Refrigerant | R-134a (GWP 1430) |
| Power supply | 230 / 1~ V/Ph/Hz |
| Defrost | Electric |
| Pre-charged line set | 10 m (code 2KTC006E) |
| Condensing unit dimensions (H×W×D) | 830 × 620 × 280 mm |
| Evaporator dimensions (H×W×D) | 215 × 1074 × 410 mm |
A monobloc is the simplest cold room solution — but it puts the compressor noise and the condenser heat right at the room. A split system moves both away. The catch was always installation: brazing, vacuum, refrigerant charge, an F-gas engineer.
GS removes the catch. Condensing unit, evaporator and the connection lines come factory pre-charged with refrigerant and terminated with self-sealing quick couplings. You mount the two units, route the line set, tighten the couplings — and the circuit closes itself, tight and charged. No brazing. No vacuum pump. No F-gas certification.
Factory pre-charged circuit. Both units and the line set arrive sealed and charged. The self-sealing couplings open the circuit only when fully threaded together.
Three line set lengths. Each model ships with a 2.5 m (P1), 5 m (P2) or 10 m (P3) pre-charged line set — pick the variant matching the distance between evaporator and condensing unit. The line set code (2KTC…) is part of the product.
Quiet rooms. The compressor sits with the condensing unit — outside, on the roof or in a side room. Inside the cold room there is only the evaporator.
Electric defrost, electronic control. Automatic defrost cycles and a clear temperature controller.
This system runs on R-134a (GWP 1430), a proven refrigerant for commercial refrigeration with stable performance across the full operating envelope.
Both units and the connection lines are factory pre-charged and sealed: in normal installation the circuit is never opened, so no refrigerant handling and no F-gas certification are required on site.
Four steps: mount the evaporator inside, place the condensing unit outside (floor or roof), route the pre-charged line set, hand-tighten the quick couplings with two spanners and switch on. The maximum line length is 10 m — choose P1/P2/P3 accordingly. Custom pipe runs are not used on this system: the pre-charged set is the circuit.
Manufacturer-recommended room volumes (35°C ambient, PIR insulation panels):
| Model | Room temperature | Recommended volume |
|---|---|---|
| BGS110 | -25…-15°C | up to 1.9 m³ |
| BGS112 | -25…-15°C | up to 3.1 m³ |
| MGS103 | -5…10°C | up to 4.9 m³ |
| BGS117 | -25…-15°C | up to 5 m³ |
| MGS105 | -5…10°C | up to 5.8 m³ |
| MGS106 | -5…10°C | up to 7.2 m³ |
| BGS218 | -25…-15°C | up to 7.4 m³ |
| MGS107 | -5…10°C | up to 9.1 m³ |
| BGS220 | -25…-15°C | up to 9.2 m³ |
| MGS110 | -5…10°C | up to 10 m³ |
| MGS211 ← this model | -5…10°C | up to 15 m³ |
| BGS330 | -25…-15°C | up to 19 m³ |
| MGS315 | -5…10°C | up to 30 m³ |
| MGS320 | -5…10°C | up to 34 m³ |
Each GS model is available with a 2.5 m (P1), 5 m (P2) or 10 m (P3) factory pre-charged line set — choose by the distance between the units.



Please review your choices for the door positioning and opening side before submitting